What was found
AFT CARGO STA 927+16; RBL 15; WL 166; FLOOR SUPPORT TRACK HAS CORROSION ON LOWER SURFACE AROUND NUT PLATES. / REMOVED AND REPLACED FLOOR SUPPORT TRACK AFT CARGO BAY STA 887-947.5+2' RBL13 P/N 147A7501U14 A-TAG# WN7682 I/A/W DWG 147A7500 REV- AND SRM 51-40-02-0G-0. REMOVED CORROSION I/A/W SRM 51-10-02-0G-0 ORIG 'T' .070' .059' REM .013' LOSS OUT OF LIMITS I/A/W SRM 53-00-53-1A-2. APPLIED CIC TO NEW FLOOR SUPPORT TRACK I/A/W AMM 51-21-91-620-802. P/N 147A7501014 A-TAG# WN7682