As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO DOOR CUTOUT; LOWER DOOR SILL WEB HAS CORROSION ON UPPER SURFACE. STA 400 TO 480+4; RBL 21 TO RBL 26 / BLENDED CORROSION ON UPPER SURFACE OF FWD CARGO LOWER DOOR SILL WEB STA 480+4" RBL 21-26, ORIGINAL THICKNESS .045, REMAINING .027, LOSS OF .018 FOUND OUT OF LIMITS IAW SRM 53-30-15-1A-1. REMOVED AND REPLACED DAMAGED DOOR SILL IAW SRM 51-40-02-0G-0 AND DWG 143A8120 REV.- RESTORED CIC TO AREA IAW AMM 51-21-91-620-802