As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
***CORROSION*** AT APU COMPARTMENT JUST NEXT TO FUEL SUPPLY LINE BS1088 LBL16; 8' ABOVE DOOR CUTOUT. MARKED / REMOVED AND REPLACED PLATE LOCATED AT APU COMPARTMENT JUST NEXT TO FUEL SUPPLY LINE BS1088 LBL16; 8' ABOVE DOOR CUTOUT FROM 7075T6; 0.050' LOT 1381333-1 PER SRM 53-80-08-0I-2 IDENTIFICATION 2 ITEM 48 TABLE 3; AND DWG #148A2433-4; INSTALLED IAW SRM 51-40-02; DWG #148A0924. 59202U 27NOV19