What was found
EVIDENCE OF CRACK ON LEFT INBOARD FAN COWL LOWER FORWARD LATCH AT RIVET HOLE. HFEC VERIFIED; CRACK MEASURES .750 IN LENGTH AND IS MARKED. / [01] ACCOMPLISHED HFEC COUNTERSINK INSP AND SURFACE INSP PER NDT 53-30-00 PROC 3 AND 51-00-00 PROC. 23 CONFIRMED CRACK IS IN THE SKIN STARTS AT FASTENER HOLE AND EXTENDS .750';[02] CHEMICALLY REMOVED PAINT ON AREA IAW SRM 51-20-01. REMOVED FASTENER IAW SRM 51-40-02. VERIFIED CRACK PER HFEC 51-00-00 PROCEDURE 23 AND COUNTERSINK HFEC PROCEDURE . COWL IS TO BE REPLACED WITH SERIVICABLE COWL ON ROUTINE CARD #TTG8Q00AYMWC;[03] C/W INSPECTION