What was found
FOUND SPOT OF CORROSION AT AFT CARGO FLOOR PANEL SUPPORT LONGITUDINAL LAP SPLICE AT BILGE AREA STA 947.5 - 3 AND BL0. DOT 82-135. / REMOVED CORROSION ON AFT CARGO COMP. FLOOR PANEL SUPPORT LONGITUDINAL (RAIL) PER REF B-737 SRM 51-10-02-0G-0; ORIGINAL MAT. .063'; MAT. LOST .021' ; MAT. REMAINING .042'; AREA FOUND OUT OF LIMITS PER REF B-737 SRM 53-00-53-1A-2 FIG. 103 DETAIL 'D' REMOVED CORRORED RAIL PER REF B-737 SRM 51-40-02-0G-0; FABRICATED NEW RAIL; MAT. USED P/N 3953025; P.O #1656330; TREATED AND PRIMED NEW RAIL PER REF B-737 AMM 51-21-41-370-802 AND 51-21-72-370-804; INSTALLED NEW RAIL PER REF B737 SRM 51-40-02-0G-0