What was found
CRACK ANGLE - CLIP LOCATED BS500B AND STR26L AT LEVEL FLOOR STRUCTURE FWD CARGO COMPARTMENT 2022-98520 / [01] REPLACED ANGLE - CLIP LOCATED BS500B AND STR26L AT LEVEL FLOOR STRUCTURE FWD CARGO COMPARTMENT IAW B737-700 SRM 51-40-02 AND DWG 143A7505 REV. -.<BR>P/N: 143A7502-159; P/O: 2021-203795. SEE INDIVIDUAL SIGN OFFS BELOW.;[02] CERTIFIED WORK PERFORMED RII<BR>SEE INDIVIDUAL SIGNOFF BELOW