What was found
CORROSION; FWD CARGO RH FLOOR TO SIDEWALL SUPPORT; UPPER SURFACE; BS 500A TO BS 500D; RBL 22 / [01] REMOVED CORROSION ON FWD CARGO R/H FLOOR TO SIDEWALL SUPPORT; UPPER SURFACE BTW BS 500A TO BS 500D RBL 22 MEASURES (1).- BS 500A+10'; L=1'. X W=.5' X D=0.010' (2).- BS 500C +18' ; L=2.' X W=1.' X D=0.015' MAX. MAT.LOSS IS 0.015' REMAINING IS 0.025' ORIGINAL THICKNESS IS 0.040' BAC1496-444. FOUND TO BE OUT LIMITS BLENDED AREAS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2 PARAGRAPH4.A.(2)(A) DETAIL E USED TOOL:MICROMETER ID:ATS1672. S/N: 65092939.DUE DATE:03:2022.;[02] VERIFIED CORRECTTION ACTION 1.;[03] REMOVED AT FWD CARGO RH FLOOR TO SIDEWALL SUPPORT; LOCATED BTW. BS.BS500A TO BS 500D; RBL 22 WL 156 IAW SRM 51-40-02-0G-0.;[04] RECEIVED NEW CHANNEL ASSY (FLOOR TO SIDEWALL SUPPORT) P/N 143A7501-186. LOT#1480585-1 LOCATED AND DRILLED AT RBL 22; - BS500A - BS500D IAW SRM 51-40-05-0G-0. DWG# 143A7500.;[08] INSTALLED AT FWD CARGO R/H FLOOR TO SIDE WALL SUPPORT P/N 143A7501-186 BTW BS 500A - 500D; RBL 22; WL 156. IAW SRM 51-40-02-0G-0; DWG#143A7500.;[09] VERIFIED INSTALLATION OF FWD CARGO R/H FLOOR TO SIDE WALL SUPPORT P/N 143A7501-186 BTW BS 500A - 500D; RBL 22; WL 156. IAW SRM 51-40-02-0G-0; DWG#143A7500.;[10] VERIFIED INSTALLATION OF FWD CARGO R/H FLOOR TO SIDE WALL SUPPORT P/N 143A7501-186 BTW BS 500A - 500D; RBL 22; WL 156. IAW SRM 51-40-02-0G-0; DWG#143A7500.