What was found
CORROSION AFT CARGO FLOOR TO SIDEWALL SUPPORT ANGLE BS 727A+2; BS 727C+8-BS 767 RBL 22 / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT RBL 21 BETWEEN BS727D+2 TO BS767 . THE LOWEST REMAINING THICKNESS .031' ON BLENDED AREA L=2.2'X W=1'XD=0.009'' ORIG. MAT. THK.=.040' FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2 STEP 4A FIG. 103 DETAIL D ;SRM 53-60-53-01-2 TOOL USED ID:ATS1671 ; DUE:10/2022;[02] VERIFIED CORRECTIVE ACTION 1.;[03] FABRICATED; LOCATED AND DRILLED FCB FLOOR TO SIDE WALL SUPPORT ANGLE BS 727 TO BS 767 RBL 22 ; MADE FROM EXTRUSION BAC1496-377#7075T62 LOT#1477731-1 IAW SRM 51-40-05-0G-0- AND SRM 53-00-53-2R-5 REPAIR-5 OK TO TREAT AND PRIME;[04] FABRICATED; LOCATED AND DRILLED FCB FLOOR TO SIDE WALL SUPPORT ANGLE BS 727 TO BS 767 RBL 22 ; MADE FROM EXTRUSION BAC1496-377#7075T62 LOT#1477731-1 IAW SRM 51-40-05-0G-0 DRW146A7500. OK TO TREAT AND PRIME;[05] FABRICATED; LOCATED AND DRILLED AFT FLOOR TO SIDE WALL SUPPORT ANGLE BS 727 TO BS 767 RBL 22 ; MADE FROM EXTRUSION BAC1496-377#7075T62 LOT#1477731-1 IAW SRM 51-40-05-0G-0 DRW146A7500. OK TO TREAT AND PRIME;[;[11] INSTALLED ON AFT CARGO FLOOR TO SIDEWALL SUPPORT ANGLE BS 727+4 TO BS 767 RBL 22 IAW SRM 51-40-02 AND DWG 146A7500;[12] VERIFIED COPRRECTIVE ACTION 11.