What was found
STA 639+2; STR-16L; WL-221 OVERWING EXIT DOOR SURROUND; STRAP CORRODED. MARKED / [01] EVALUATED CORRODED AREA ON SUPPORT STRAP OVERWING EXIT DOOR BS639+2'' STR-16L WL 221 AND NO FOUND ALLOWABLE DAMAGE ON SRM 53-40-15-1A-1; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9.;[02] VERIFIED EVALUATED CORRODED AREA ON SUPPORT STRAP OVERWING EXIT DOOR BS639+2'' STR-16L WL 221 AND NO FOUND ALLOWABLE DAMAGE ON SRM 53-40-15-1A-1; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9.;[03] REMOVED OVERWING EXIT DOOR SURROUNT STRAP PN#144A8223-3 IAW SRM 51-40-02;[04] RECEIVED STRAP WITH ITEM HFAB53-SP-002. P/O 859518/1. CUSTOMER RO N.- 859518-SWA. RECEIVED (STRAP) MATERIAL 2024-T3 BARE TREATED WITH BORIC ACID-SULFURIC ACID ANODIZED PER BAC5632;REV E; DATED 09-OCT-20; CLASS 1. PER P/O:859522. LOCATED AND DRILLED STRAP IAW. SRM 51-40-05-0G-0. DWG# 144A8201. OK TO PRIME;[05] INSPECTED ACTION 4; OK TO INSTALL;[06] APPLIED TWO LAYERS BMS10-11;TYPE 1 PRIMER ON STRAP PER SOPM 20-41-02; DWG#144A8223 REV:D. OK TO INSTALL STRAP.;[07] INSPECTED ACTION 6;[08] INSTALLED OVERWING EXIT DOOR SURROUND STRAP STA 639+2 STR 16L WL 221 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG # 144A8201;[09] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 8.;[10] CORRECTED MEASUREMENTS.;[11] VERIFIED FAULT TTG8Q00B5H4W IS COMPLETE.