What was found
B.S. 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IS CRACKED AT R.B.L. 8 W.L. 164. / [01] HFEC INSPECTED PER 737NDT PART 6 51-00-00 PROCEDURE 23. VERIFIED CRACKED CONDITION. TOOL N500 IS000681.;[02] B.S. 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE AT R.B.L. 8; W.L. 164. FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE IN SRM ; IT WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9.C.;[03] REMOVED FASTENERS (UPPER ATTACH ANGLE) COMMO05] FORMED NEW REPLACEMENT B.S 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE BETWEEN RBL 6 AND RBL 63 WL 164 MATERIAL USED 2024T0 ; 0.063' LOT # 1468138-1 IAW DWG # 111A1322-6 ; SENT TO O.S.S FOR HEAT TREAT TO T42;[06] VERIFIED FORMED NEW REPLACEMENT B.S 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE BETWEEN RBL 6 AND RBL 63 WL 164 MATERIAL USED 2024T0 ; 0.063' LOT # 1468138-1 IAW DWG # 111A1322-6 ; SENT TO O.S.S FOR HEAT TREAT TO T42.;[07] UPDATED STEPS 1 ; 2 AND 3;[08] RECEIVED PART FROM O.S.S NEW LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE HFAB35-AA-002 (2024T42;0.063'' CLAD SHEET) LOT # 1468138-1 DWG # 111A1322-6 CUSTOMER RO. NO. 859502-SWA JOB#547882.;[09] FABRICATED; LOCATED AND DRILLED NEW LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IAW SRM 51-40-05-0G-0 AND DRAWING#111A1322-6.<BR>OK TO TREAT AND PRIME.;[12] VERIFIED CORRECTIVE ACTION #11;[13] INSTALLED NEW LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE PER SRM 51-40-02 AND DWG 111A1000