What was found
EXTERNAL LOWER FUSELAGE; MID FORWARD FAIRING 191D; DOUBLER AROUND OPENING FOR ATTACHED PANEL 191E IS CORRODED AT 2 EA HINGE LOCATIONS. / BLENDED CORROSION AT LOWER FUSELAGE FAIRING 191D DOUBLER AROUND OPENING FOR ATTACHED PANEL 181E. ORIGINAL .100; REMAINING .060; LOSS OF .040' FOUND OUT OF LIMITS IAW SRM 53-30-70-1A-1. REMOVED AND REPLACED DOUBLER IAW SRM 51-40-02-0G-0 AND DWG 149A7153 REV. D. APPLIED CIC TO NEW DOUBLER AND DISTURBED AREAS IAW AMM 51-21-91-620-802 TOOL # 27213 DUE: 02/05/2020