What was found
***CORROSION*** ON AFT CARGO R/H FLOOR TO SIDEWALL SUPPORT CHANNEL STA 727 - 767 RBL 21 WL 155 / FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM. REMOVED; FABRICATED; TREATED + PRIMED; AND INSTALLED AFT CARGO RH FLOOR TO SIDEWALL SUPPORT CHANNEL STA 727-767 RBL 21 WL 155 IAW SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; AMM 51-21-73-370-804; AMM 51-21-41-370-802 SRM 51-40-10-2R-0; BOEING DWG # 146A7500; # 146A7502 59125U 10/2/19