What was found
A-061 DOT 029 FWD CARGO PIT AFT FLOOR STRUCTURE AT STA 500I LBL 23 TO RBL 23 WL 155 CORRODED UPPER SURFACE / [01] REMOVED CORROSION IAW SRM 51-10-02 10X MAGNIFY MAXIMUM MATERIAL REMAINING .056 .050 MATERIAL REMAINS OUT OF LIMITS IAW SRM 53-30-08-1A-1 AAR TOOL NO. 36646 DUE DATE 10/06/22;[02] MINIMUM REMAINING ALLOWED .056' OUT OF LIMITS. VERIFIED ITEM 1;[03] VERIFIED OUT OF LIMITS;[04] REMOVE CORRODED SUPPORT ANGLE IAW SRM 51-40-02-0G-0;[05] LOCATED AND DRILLED NEW SUPPORT ANGLE PN: 143A9485Y35 ATAG WN11677 IAW DWG 143A7902 REV B;[06] VERIFIED STEPS 4 AND 5 ARE COMPLETE;[07] VERIFIED STEPS 4; 5 AND 6;[08] INSTALLED NEW RAIL ASSY IAW SRM 51-40-02-0G-0 AND BOEING DWG 143A7902 ID:0257 REV:B. APPLIED CIC IAW AMM 51-21-91-620-802.;[09] REMOVED CORROSION FROM FWD CARGO COMPARTMENT; AFT BULKHEAD LOWER ANGLE. OUT OF LIMITS. REMOVED AND REPLACED LOWER ANGLE ASSY - SEE ABOVE FOR COMPLETED WORK.;[10] VERIFIED ITEM 8 AND 9<BR><BR>AUDIT C/W