What was found
A22-33; AFT PIT FLOOR PANEL 140AF; CORROSION AROUND THE PERIMETER (SECONDARY STRUCTURE) / [01] FOUND PANEL 140AF TO BE OUT OF LIMITS DUE TO THE DAMAGE BEING MORE THAN 20'.IAW SRM 53-00-53-1A-1;[02] VERIFIED NEW FLOOR PANEL MATERIAL AS P/N 2024-T3-071 ATAG##A115239 IAW AMM 25-52-01-201-801;[03] VERIFIED STEP 2;[04] BEGAN FABRICATING NEW FLOOR PANEL 140AF IAW SRM 51-40-05-OG-O;[05] FABRICATED FLOOR PANEL 140AF IAW AMM 25-52-01-20-801.<BR>WORK PERFORMED BY BERNARD BEMKE 27266;[06] VERIFIED STEP 1<BR><BR>OK TO TREAT AND PRIME;[07] CORRECTION VERIFIED STEP 5;[08] TREATED AND PRIMED FLOOR PANEL IAW AMM 25-52-01-20-801. <BR>WORK PERFORMED BY BERNARD BEMKE 27266;[09] FABRICATED REPLACEMENT PANEL 140AF IAW AMM 25-52-01-20-801. <BR>WORK PERFORMED BY BERNARD BEMKE 27266;[10] VERIFIED STEPS 8 & 9<BR>AUDIT CW