What was found
CRACK INSPAR RIB LOCATED STAB STA 120.30 AND 27 INCH FROM FRONT SPAR LT HORIZONTAL STAB 2022-109060 / [01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N: 210138503 DUE DATE: 05-MAR-22;[02] TOOL USED EDDY CURRENT EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101U102020; CAL DUE DATE: 01-JUN-22;[03] PERFORMED REPAIR INSPAR RIB LOCATED. STAB TA 120.30 AND 27 INCH FROM FRONT SPAR LT HORIZONTAL STAB SRM 55-10-09-2R-5 REPAIR 5;[04] CORRECTED STEP 3 PERFORMED REPAIR INSPAR RIB LOCATED. STAB TA 120.30 AND 27 INCH FROM FRONT SPAR LT HORIZONTAL STAB IAW B737-700 SRM 55-10-09-2R-5 REPAIR 5;[05] CERTIFIED STEP 4 COMPLETED; ITEM RII