What was found
CRACK IN BEAR STRAP BS294 BETWEEN STR 8R AND 9R AT FWD GALLEY DOOR. MARKED IN RED. CRACK LENGTH .250 IN FROM EDGE OF FASTENER GOING AFT AND UP. FOUND ON HFEC INSP / [01] VERIFIED SRM 53-10-01-2R-6 IS APPLICABLE FOR REPAIR TO FUSELAGE SKIN AND BEAR STRAP AT FWD GALLEY DOOR UPPER FWD CUTOUT CORNER.;[09] FABRICATED 1 EA. DOUBLER WITH 2024-T3#0.100 IN.; LOT # 1443470-1; 1 EA. TRIPLER WITH 2024-T3#0.063 IN. LOT #1478284-1; 1 EA. TAPERED SHIM WITH 2024-T3#0.160 IN. LOT #1419195-1 & 1 EA. FLAT SHIM WITH 2024T3#0.063 IN. LOT #1478284-1; PER SRM 53-10-01-2R-6; TABLE 201; OK TO APPLY CHEMICAL CONVERSION COATING AND IMPACT PRIMER.;[10] VERIFIED CORRECTIVE ACTION ITEM 9.<BR>OK TO APPLY CHEMICAL CONVERSION COATING AND IMPACT PRIMER.14] FABRICATED 1 EA. FILLER FROM 2024-T3 0.090' LOT # 1468724-1 PER SRM 53-10-01-2R-6; TABLE 201; APPLIED CHEMICAL CONVERSION COATING AND PRIMER.;