What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 907+6; BS 907+10; BS 907+13; BS 907+17. / [01] REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT RBL21 BS 907+6 MEASURED 1.3'L X 1'W AND 0.005' DEEP FOUND OUT OF LIMITS<BR><BR>REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT RBL21 BS 907+6 MEASURED 1'L X 1'W AND 0.0035' DEEP FOUND IN LIMITS<BR><BR>REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT RBL21 BS 907+6 MEASURED 2'L X 1'W AND 0.0025' DEEP FOUND IN LIMITS<BR><BR>REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT RBL21 BS 907+6 MEASURED 0.8'L X 0.5'W AND 0.0065' DEEP ORIGINAL THICKNESS OF 0.040' FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2<BR><BR>CAL ID DIAL DEPTH GAUGE<BR>ATS1225<BR>S/N UNKNOWN<BR>DUE 07/2022;[05] FABRICATED REPLACEMENT FLOOR TO SIDEWALL SUPPORT USING ITEM: BAC1496-377#7075T62 LOT: 1477731-1 IAW SRM 51-40-02; SRM 51-40-08 SRM 51-40-05 AND DWG 147A7501 ID:0006 REV: A. APPLIED CHEMICAL CONVERSION COATING TO REPLACEMENT SIDEWALL SUPPORT IAW SOPM 20-41-02. OK TO APPLY PRIMER.;[06] FABRICATED REPLACEMENT FLOOR TO SIDEWALL SUPPORT USING ITEM: BAC1496-377#7075T62 LOT: 1477731-1 IAW SRM 53-60-53-0I-2 TABLE 2 ITEM 2; SRM 51-40-02; SRM 51-40-08 SRM 51-40-05 AND DWG 147A7501 ID:0006 REV: A. APPLIED CHEMICAL CONVERSION COATING TO REPLACEMENT SIDEWALL SUPPORT IAW SOPM 20-41-02. OK TO APPLY PRIMER.