What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 20 BS 787+2; BS 787+6; BS 787+10; BS 787+14; BS 807+2; BS 807+6; BS 807+10; BS 807+14. / [01] REMOVED CORROSION FROM BS787+2 TO BS807+14 LBL 20 IAW SRM 51-10-02-0G-0 STEP 15<BR><BR>787+2=0.004' L=.5' W=.5'<BR>787+6=0.003' L=2' W=1'<BR>787+10= 0.005' L=.5' W=.5'<BR>787+14=0.006' L=.5 W=.5'<BR>807+2=0.003' L=.5' W=.5'<BR>807+6=0.007' L=.5' W=.5'<BR>807+10=0.004' L=1' W=.5'<BR>807+14=0.006' L=.5' W=.5'<BR><BR>DEEPEST DAMAGED IS AT BS 807+10; 0.007' MATERIAL REMOVED. ORIGINAL THICKNESS 0.040'. REMAINING MATERIAL 0.033' FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-0I-2 AND SRM 53-00-53-1A-2<BR><BR>TOOL USED<BR>DIAL DEPTH GAUGE ID: ATS1225 S/N: UNKNOWN;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] FABRICATED LOCATED AND DRILLED AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT LBL 20 BS 727 TO BS TO 847 MATERIAL USED BAC1496-377=7075T62 EXTRUSION LOT:1477731-1 IAW SRM 51-40-05 AND DWG 146A7502 REV:A.;[04] FABRICATED LOCATED AND DRILLED AFT CARGO BAY SPLICE TO SIDEWALL SUPPORT AT LBL 20 BS 727E+10 MATERIAL USED BAC1496-377=7075T6 EXTRUSION LOT#1477731-1 IAW SRM 51-40-05 AND SRM 53-00-53-2R-6 REPAIR 6.;[05] VERIFIED CORRECTIVE ACTION 3 AND 4;[06] APPY CHEMICAL CONVERSION COATING AND PRIMER.13] INSTALLED FLOOR TO SIDEWALL SPLICE REPAIR BETWEEN BS 727E TO 747 L/H LBL 20 IAW SRM 53-00-53-2R-6 REPAIR 6.;[14] VERIFIED CORRECTIVE ACTIONS 12 AND 13.