What was found
DAMAGE ON FWD CARGO BAY STRINGER AT BS 540 R/H STRINGER 24. / [01] EVALUATED CRACK ON FCB STR 24 R/H BS 536 ; STRINGER DAMAGE FOUND TO BE OUT LIMITS IAW SRM 53-00-03-1A-1 FIG 103[07] RECEIVED; AND VERIFIED NEW STRINGER SECTION HFAB53-STS-011 FORMED; HEAT TREATED AND DRY PEN INSPECTED ; LOCATED BTW B/S 500D+10'-540 STR 24R/H ON CUSTOMER RO NO :859027-SWA PO: 859027/1 AND HAT SECTION :HFAB53-HS-011 LOCATED BTW B/S 500D-520 CUSTOMER RO NO :859025-SWA PO:859025/1. <BR>LOCATED AND DRILLED IAW SRM 53-00-03-2R-1 REPAIR 1 AND DWG 143A3230 REV:B; DWG 143A0060 REV:A.<BR> OK TO PRIMER;[08] VERIFIED CORRECTIVE ACTION 7.;