What was found
CORROSION ON FWD CARGO BAY DOOR THRESHOLD AT RBL 29 BS 460+12. / [01] SRM 53-30-15-1A-1 IS APPLICABLE<BR><BR>REMOVED CORROSION FROM FWD CARGO BAYI DOOR THRESHOLD WEB AT RBL29 BS460+12 N AREA OF 2.2'X1.2'X.005' ORIGINAL MATERIAL THICKNESS .045' FOUND TO BE OUT OF LIMITS IAW SRM 51-10-02-0G-0 AND SRM 53-30-15-1A-1<BR><BR>DEPTH GAUGE<BR>ATS2677<BR>S/N UNKNOWN<BR>11/2022;[02] VERIFIED CORRECTIVE ACTION 1;[03] RECEIVED NEW WEB P/N: 654A0003-58 PO NUMBER: P2455495-1. LOCATED AND DRILL NEW WEB IAW SRM 51-40-02; SRM 51-40-05; SRM 51-40-08 AND DWG 143A8122 ID:0010 REV: -.;[04] RECEIVED NEW WEB P/N: 654A0003-58 PO NUMBER: P2455495-1. LOCATED AND DRILL NEW WEB IAW SRM 51-40-02; SRM 51-40-05; SRM 51-40-08 AND DWG 143A8122 ID:0010 REV: -.;[05] PART REQUIREMENT;[06] VERIFIED CORRECTIVE ACTIONS 3-5. ALL WORK ACCOMPLISHED.