What was found
CABIN FLOORBOARD 242AF AFT I/B CORNER DAMAGED. FOUND MULTIPLE UPPER SURFACE CUTS AND DENTS. FOUND DELAMINATED SPOTS AND 2 ADDITIONAL CORNERS DAMAGED. REPAIRED SMALL DAMAGE ON MAIN CABIN FLOOR PANEL #242AF AFT I/B CORNER IAW SRM 53-00-50-2R-1. PERFORMED TAP TEST ON REPAIRED AREA FOUND NO DELAMINATION IAW NDT 51-05-01 SECTION 5. REPAIRED MULTIPLE UPPER SURFACE CUTS AND DENTS; DELAMINATED SPOTS AND 2 ADDITIONAL CORNERS DAMAGE ON MAIN CABIN FLOOR PANEL #242AF IAW SRM 53-00-50-2R-1. PERFORMED TAP TEST ON REPAIRED AREAS FOUND NO DELAMINATION IAW NDT 51-05-01 SECTION 5.