As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT BILGE LATERAL FLOOR SUPPORT ANGLE (SECONDARY STRUCTURE) LOWER SURFACE IS CORRODED AT BS 947; LBL 10; WL 199. / VERIFIED NO RECORDED ALLOWABLE DAMAGE LIMITS ON AFT FIT FLOOR SUPPORT/BULKHEAD SUPPORT AT STA 947 OUT OF LIMITS IAW SRM 51-10-02-0G-0. REMOVED AND REPLACED STA 947 BULKHEAD SUPPORT ASSEMBLY P/N 149A8117-6 ATAG WN8897 IAW SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 + DWG 149A8110 REV A