What was found
CORROSION ON FLOOR BEAM BS 312 LBL 50 WL 208. / [01] REMOVED CORROSION ON FLOOR BEAM BS 312 LBL 50 WL 208 IN A 2.9' X 2.2' AREA IAW SRM 51-10-02-0G-0[17] INSTALLED FLOOR PANEL 221DF AND 221BF USING NEW BACN11AF CLIPNUTS PER MM 51-40-02;[18] VERIFIED BACN11AF CLIPNUTS INSTALLED; IN CORRECTIVE ACTION ITEM 17; AWAITING ENGINEERING APPROVAL.;[19] REPAIRED DAMAGE ON FLOOR BEAM BS 312; LBL 50; WL 208 PER EA 22-153-00830.;[20] VERIFIED CORRECTIVE ACTION #19;[21] EDITED CORROSION LEVEL ON MEASUREMENT TABLE.