What was found
CORROSION ON AFT ENTRY MOPSILL STA 900-988; L/H; WL 208. / [01] EVALUATED CORROSION ON AFT ENTRY MOPSILL STA 900-988; L/H; WL 208. FOUND TO HAVE 100 PERCENT MATERIAL LOSS. OUT OF LIMITS PER SRM 53-70-15-1A-1. REPLACEMENT OF PART IS APPLICABLE SRM 51-10-02-0G-0.;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] REMOVED AFT ENTRY MOPSILL STA 900-988 L/H WL 208 IAW SRM 51-40-02-0G-0;[04] RECEIVED;LOCATED AND DRILLED NEW AFT ENTRY DOOR MOPSILL P/N 147A8540U7ATSMRO BS 887-1006 L/H WL 208 IAW SRM 51-40-05-0G-0 AND DWG 147A8501.;[05] VERIFIED CORRECTIVE ACTION STEP 4.;[06] OK TO INSTALL NEW AFT ENTRY DOOR MOPSILL P/N 147A8540U7ATSMRO BS 887-1006 L/H WL 208 IAW SRM 51-40-05-0G-0 AND DWG 147A8501.;[07] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 6. OK TO INSTALL NEW AED MOPSILL GIVEN.;[08] INSTALLED 100% TEMPORARY AND PERMANENT FASTENER WITHIN SEALANT SQUEEZE OUT TIME I.A.W SOPM 20-50-19;[09] VERIFIED CORRECTIVE ACTION #8;[10] INSTALLED AED MOPSILL I.A.W SRM 51-40-02-0G-0 AND DWG 147A8501.;[11] VERIFIED STEP 10.;[12] UPDATED MEASUREMENT TABLE.;[13] UPDATED MEASUREMENT TABLE.;[14] REMOVED AND REPLACED AED MOPSILL I.A.W SRM 51-40-02-0G-0 AND DWG 147A8501 ALL AMT BLOCK COMPLETED;[15] VERIFIED CORRECTIVE ACTION 14.