As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BS 272; WL 207; RBL 24 FLOOR ANGLE ATTACH STRUCTURE CRACKED BELOW FLOOR / FABRICATED WALL SUPPORT CHORD AT STA 272 RBL 10.9 FLOOR; ACCOMPLISHED MATERIAL AND FINISH SUBSTITUTE. I.A.W. E.A. 192547 IR AND E.A. 1-753-36209 REV IR REMOVED AND REPLACED I.A.W. DWG 141A5210 REV:- AND SRM 51-40-02-06-0