What was found
FLOOR ANGLE SUPPORT CRACKED AT APPROX. STA 540 LBL1 / REPLACED FLOOR PANEL BREAK ASSEMBLY PER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR ANGLE SUPPORT CRACKED AT APPROX. STA 540 LBL1 / REPLACED FLOOR PANEL BREAK ASSEMBLY PER SRM 51-40-02.