What was found
CORROSION ON FLOOR SUPPORT STA 954; RBL 8; WL 208. / [01] REMOVED CORROSION ON FLOOR SUPPORT STA 954; RBL 8; WL 208. MAX MATERIAL REMOVED WAS .018' 1' BY .5' FROM .075. OUT OF LIMITS PER SRM 53-70-51-1A-1.MEASURED DEPTH WITH SPHERICAL MICROMETER ID# IS000459; S/N 67127987; EXP 01/2023.;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED INTERCOSTAL BETWEEN STA 947-967; RBL-8; WL-208; PER SRM 51-40-02-0G-0; 7.D.(6).;[04] LOCATED AND DRILLED NEW INTERCOSTAL PER SRM 51-40-05-0G-0; REF BOEING DWG 147A5760; SHEET 1; VIEW 1B3.;[05] VERIFIED CORRECTIVE ACTION 4.;[06] INSTALLED NEW INTERCOSTAL AT STA 947-967; RBL-8; WL-208 PER SRM 51-40-02-0G-0 7.D; REF BOEING DWG 147A5760; SHEET 1; VIEW 1B3 AND FLAGNOTE 2.;[07] VERIFIED CORRECTIVE ACTION 6.;[08] COMPLETED STEP 1; LOCATE/DRILL FLOOR FASTENER HOLES.;[09] VERIFIED STEP 1 AND CORRECTIVE ACTION 8.;[10] REMOVED CORROSION FROM FLOOR SUPPORT AT STA 954; RBL-8; WL-208; MATERIAL REMOVED OVER 1' X 0.5' AT MAX DEPTH OF 0.018' FROM 0.075' ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1.<BR>REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL AT STA 947-967; RBL-8; WL-208 PER SRM 51-40-02-0G-0 7.D; REF BOEING DWG 147A5760; SHEET 1; REV B.;[11] VERIFIED CORRECIVE ACTION 10.