What was found
CORROSION FLOOR STRUCTURE BEAM LOCATED BS986.5 LBL43 AND WL208.1 AT AFT GALLEY AREA 2022-131775 / [01] TOOL USED P/N: 45MG; S/N: 130063701; DUE DATE: 11-MAY-22;[02] TOOL USED. EDDY CURRENT EQUIPMENT. P/N: NORTEC 500D. S/N: N500X12101V022233. DUE DATE: 02-JUN-22.;[03] TOOL USED CALIPER P/N 500-197-30; S/N: A18135088; DUE DATE: 01-AUG-22;[04] REPAIRED FLOOR STRUCTURE BEAM LOCATED BS986.5 LBL43 AND WL208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 ALTERNATIVE 3 FIGURE 204 SEE INDIVIDUAL SIGN-OFFS BELOW.;[05] REPAIRED FLOOR STRUCTURE BEAM LOCATED BS986.5 LBL43 AND WL208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 ALTERNATIVE 3 FIGURE 204 SEE INDIVIDUAL SIGN-OFFS BELOW... RII ITEM