What was found
CRACK FLOOR STRUCTURE BEAM LOCATED BS294.5 AND RBL55 AT FWD GALLEY AREA 2022-131749 / [01] TOOL USED EDDY CURRENT EQUIPMENT PN NORTEC 600D SN 60007161486 DUE DATE 06-DEC-22.;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 02-FEB-23; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 02-FEB-23.;[03] REPAIRED STRUCTURE FLOOR BEAM LOCATED BS 294.5 AND RBL 55 AT FWD GALLEY AREA. IAW B737-700 SRM 53-10-51-2R-16 ALTERNATIVE 2 PARAGRAPH.4D TABLE 201 REPAIR 16 FIGURE 202. ?SEE INDIVIDUAL SIGNOFFS BELOW?.;[04] TASK CARD COMPLETED <BR>RII<BR>SEE INDIVIDUAL SIGN OFFS BELOW