What was found
VERTICAL STABILIZER PANEL MATING SURFACES ON THE LEFT FUSELAGE FIN TO BODY INTERFACE CLOSURE ANGLE HAVE AREAS OF CHAFFING FROM CONTACT OF CLOSURE PANELS. / [01] REMOVED LEFT AFT SKATE ANGLE PER SRM 51-40-02.;[02] REMOVED AND REPLACED L/H AFT SKATE ANGLE PER SRM 51-40-02.;[03] REMOVED AND REPLACED PER SRM 51-40-02;[04] C/W INSPECTION;[05] C/W INSPECTION;[06] REMOVED AND REPLACED PER SRM 51-40-02