What was found
CRACKED STIFFENER AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS914 RBL10. / [01] PRIOR TO REMOVAL;FOUND PART TO HAVE NO SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT;PER SRM 51-10-02 STEP 9.;[02] REMOVED STIFFENER AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS914 RBL10;IAW SRM 51-10-02;AND 51-40-02.;[03] VERIFIED CORRECTIVE ACTIONS #1 AND #2;[04] LOCATED AND DRILLED NEW STIFFENEER WITH P/N 147A7221Y32;LOT#1485029-1;PO#860513;IAW SRM 51-10-05;AND DWG#147A7221 REV.D.OK TO INSTALL.;[05] VERIFIED DRILL UP; IAW SRM 51-10-05;AND DWG#147A7221 REV D.OK TO INSTALL.;[06] INSTALLED STIFFENER AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS914 RBL 10.IAW SRM 51-40-02 AND DWG#147A7221 REV D.ALL MAINTENANCE ACTION ARE COMPLETED REQUIRE FINAL BUY OFF.;[07] CORRECTION TO CORRECTIVE ACTION 4 HAS TO BE P/N 147A7221-32; LOT#1485471-1;PO#861006.;[08] VERIFIED ITEM 6 CORRECTIVE ACTIONS.;[09] VERIFIED ITEM 7 CORRECTIVE ACTIONS.