What was found
L/W T/E PANEL 561CB HAS SEVERAL PULLED FASTENER HOLES (MARKED) / [01] IDENTIFIED PANEL MATERIAL IAW SRM 57-51-01-0I-1 FIG. 3; TABLE 3; ITEM 10. <BR><BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 57-51-01-1A-1; PARA. 4.B.(5). <BR><BR>DAMAGE WILL BE REPAIRED ACCORDING TO SRM 51-70-04-2R-9; AS REQUIRED BY SRM 57-51-01-2R-1; PARA. 4.B.(2); TABLE 202. <BR><BR>COUNTERSUNK DAMAGED FASTENER HOLES TO REMOVE DAMAGE; TAP TESTED AREA - NO DISBONDS NOTED; CLEANED AND PREPARED REPAIR AREA ACCORDING TO SRM 51-70-04-2R-9; PARA'S 4.A THRU 4.C.;[02] VALIDATED REPAIR PER SRM 51-70-04-2R-9;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VALIDATED REPAIR PER SRM 51-70-04-2R-9;[04] POTTED FASTENER HOLES WITH 9390 RESIN LOT JH1GAA7833 AND MILLED GLASS FIBERS LOT 1437038-1 AND SET FOR CURE IAW SRM 51-70-04-2R-9 PARA 4 D-F<BR><BR>HOT BOND MACHINE ID NCX000526; S/N 12051216;[05] CURED SLURRY; SANDED SLURRY TO CONTOUR; PREPPED AND CLEANED REPAIR AREAS IAW SRM 51-70-04-2R-9 PARA 4.F-I;[06] FABRICATED REPAIR PLIES FROM BMS 9-3 (1581) LOT# 1475360-2; INSTALLED REPAIR PLIES WITH 9390 RESIN LOT# JH1GAA7833; VACUUM BAGGED AND SET FOR CURE IAW SRM 51-70-04-2R-9 PARA 4.J-M<BR><BR>HOT BONDER ID ATS532