What was found
CORROSION ON B.S. 986.5 FLOOR BEAM; UPPER SURFACE; AT R.B.L. 20-45; W.L. 208.1. / [01] REMOVED CORROSION FROM BS 986.5 FLOOR BEAM UPPER FLANGE AT FASTENER HOLES MAXIMUM MATERIAL REMOVED AT RBL 43' IN AREA OF 1.5' X 1' ORIGINAL MATERIAL THICKNESS 0.150' REMAINING MATERIAL THICKNESS 0.124' FOUND TO BE OUT OF LIMIT IAW SRM 53-70-51-1A-1 DET.4H (2B) FIG 103 -C<BR>TOOLS USED DIGITAL CALIPER ID#ATS2503; S/N A19335646;[18] INSTALLED REPAIR PART IAW SRM 53-70-51-2R-6 REPAIR 6;[19] VERIFIED CORRECTIVE ACTION #18;[20] FILLED THE BLEND AREA WITH BMS 5-92 TYPE I IAW SRM53-70-51-2R-6 REPAIR 6 AND IAW SRM 51-70-01-2R-0;[21] VERIFIED ITEM 20 CORRECTIVE ACTIONS.;[22] APPLIED BMS 10-11 PRIMER TO THE REWORKED AREA IAW SR 53-70-51-2R-6 REPAIR 6;[23] VERIFIED CORRECTIVE ACTION 22.;[24] JOB COMPLETED;[25] VERIFIED ITEM 24 CORRECTIVE ACTIONS.