What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 400+18; BS 420+9; BS 420+10; BS 420+13; BS 440+2; BS 500+10; BS 500+15; BS 500+19; BS 500A+2; BS 500A+7. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 440+2 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS1225;[02] VERIFIED ACTION 1;[03] REMOVED FLOOR TO SIDEWALL SUPPORT BTW BS 396 AND 500I LBL 24 WL 156 IAW SRM 51-40-02-0G-0.;[04] UPDATED PART USE;[05] LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT BS 396 TO BS 500I LBL 24 WL 146 PER SRM 51-40-05-0G-0 AND DWG 143A7500. OK TO INSTALL FLOOR TO SIDEWALL SUPPORT;[06] VERIFIED CORRECTIVE ACTION 5- OK TO INSTALL NEW FLOOR TO SIDEWALL SUPPORT.;[07] BEGAN INSTALLING FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-02-0G-0 AND DWG 143A7500;[08] CORRECTION ACTION: LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT BS 396 TO BS 500I LBL 24 WL 156 PER SRM 51-40-05-0G-0 AND DWG 143A7500. OK TO INSTALL FLOOR TO SIDEWALL SUPPORT;[09] INSTALLED NEW FLOOR TO SIDEWALL SUPPORT P/N 143A7501-187 AT BS 396 TO BS 500I LBL 24 WL 156 PER SRM 51-40-02-0G-0 AND DWG 143A7500.;[10] VERIFIED NEW FLOOR TO SIDEWALL SUPPORT P/N 143A7501-187 INSTALLED AT BS 396 TO BS 500I LBL 24 WL 156 PER SRM 51-40-02-0G-0 AND DWG 143A7500.