What was found
CORROSION ON FWD CARGO BAY FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 400+6; BS 400+10; BS 400+14. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 400+10 REMOVED 0.020' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS1225;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] REMOVED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL24 BS396 TO BS420; PER SRM 51-40-02-0G-0.;[04] FABRICATED LOCATED AND DRILLED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL24 BS396 TO BS420; PER SRM 51-40-05-0G-0; DWG 143A7500 AND DWG 143A7501; APPLIED CHEMICAL CONVERSION COATING AND PRIMER PER AMM 51-21-41-370-802; AMM 51-21-72-370-804.<BR> MATERIAL USED BAC1496-444#7075T62 LOT 1479718-1.<BR><BR>OK TO INSTALL.;[05] VERIFIED CORRECTIVE ACTION ITEM 3-4; OK TO INSTALL; NUTPLATES REQUIRED BEFORE FINAL COMPLETION..;[06] INSTALLED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT INCLUDED NEW NUTPLATE AT RBL24 BS396 TO BS420; PER SRM 51-40-02-0G-0; DWG 143A7500 AND DWG 143A7501;[07] VERIFIED CORRECTIVE ACTION STEP 6 COMPLETED;[08] VERIFIED CORRECTIVE ACTION STEP 6 AND 7 COMPLETED