What was found
CORROSION ON FWD CARGO BAY FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500A+7; BS 500A+11; BS 500A+15; BS 500D+11; BS 500D+19; BS 500F+11; BS 500G+11; BS 500G+15; BS 500H+2; BS 500H+16. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500D-19 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS1225;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT BS 500A-500I RBL 24 WL 156 IAW SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT BS 500A-500I RBL 24 WL 156 IAW SRM 51-40-05-0G-0 AND DWG 143A7500.;[05] VERIFIED CORRECTIVE ACTION STEPS 3 AND 4.;[06] OK TO INSTALL;[07] OK TO INSTALL FWD CARGO BAY BS 500A-500I RBL 24 BS FLOOR TO SIDEWALL SUPPORT;[08] UPDATED PART USE;[09] INSTALLED NEW FLOOR TO SIDEWALL SUPPORT P/N 143A7501U188 AT BS 500A-500I RBL 24 WL 156 IAW SRM 51-40-02-0G-0 AND DWG 143A7500.;[10] VERIFIED CORRECTIVE ACTION 9.;[11] VERIFIED FAULT COMPLETED.