What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500A+11; BS 500A+15; BS 500A+19; BS 500B+2; BS 500B+19; BS 500C+2; BS 500C+11; BS 500D+7; BS 500E+7. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500B+19 REMOVED 0.020' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS1225;[02] SUPPORT WILL BE REMOVED AND REPLACED ON FAULT TTG8Q00BERHG .;[03] VERIFIED