What was found
CORROSION ON FWD CARGO BAY FWD CARGO BAY DOOR THRESHOLD AT RBL 28 BS 440+9; BS 440+14; BS 480+4. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 461 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.045' FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-1 USING ATS TOOL ID ATS1225;[02] VERIFIED CORRECTIVE ACTION 1. OUT OF LIMITS.;[03] REMOVED; LOCATED AND DRILLED NEW FWD CARGO BAY DOOR THRESHOLD AT RBL 28 BS 440 - BS 492 IAW SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; SRM 51-40-08-0G-0 AND DWG 143A8330;[04] VERIFIED CORRECTIVE ACTION 3;[05] OK TO INSTALL NEW FWD CARGO BAY DOOR THRESHOLD WEB BS 440-BS 492 RBL 28;[06] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 5. OK TO INSTALL NEW FCB DOOR THRESHOLD WEB GIVEN.;[07] APPLIED CIC TO UNDERSIDE OF FCB DOOR THRESHOLD WEB AND STRUCTURAL AREA AT BS 440-BS 492 RBL 28 IAW AMM 51-21-91-620-802 INSTALLED NEW FCB DOOR THRESHOLD WEB BS 440-BS 492 RBL28 IAW SRM 51-40-02-0G-0 AND BOEING DWG 143A8330;[08] JOB TASK IS ACCOMPLISHED;[09] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 7.;[10] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 8.