What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 20 BS 747+18; BS 767+7; BS 767+10; BS 767+14; BS 767+18. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 767+7 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS1225;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED FLOOR TO SIDEWALL SUPPORT AT BS 727 TO BS 847 LBL 20 PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT AT BS 727 TO BS 847 LBL 20 PER SRM 51-40-05-0G-0 AND DWG 146A7500. OK TO INSTALL FLOOR TO SIDEWALL SUPPORT;[05] INSPECTED ACTION 4; OK TO INSTALL;[06] INSTALLED FLOOR TO SIDEWALL SUPPORT AT BS 727 TO BS 847 LBL 20 PER SRM 51-40-02-0G-0 AND DWG 146A7500;[07] RII INSPECTED;[08] INSPECTION COMPLETE