What was found
CORROSION ON AFT CARGO BAY AFT SHIELD AT RBL 22 BS 847+8; BS 847+12; BS 847+15. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED AFT CARGO BAY SHIELD AT RBL 22 BS 847 TO BS 867 PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED SHIELD AT BS 847-BS 867 RBL22 PER SRM 51-40-05-0G-0 AND DWG 146A0081. OK TO INSTALL SHIELD;[05] VERIFIED CORRECTIVE ACTION 4; OK TO INSTALL GIVEN.;[06] INSTALLED AFT CARGO BAY SHIELD AT RBL 22 BS 847 TO BS 867 PER SRM 51-40-02-0G-0 AND DWG 146A0081;[07] RII INSPECTION COMPLETE;[08] INSPECTION COMPLETE