What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 20 BS 887+8; BS 887+15; BS 927+17; BS 947. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 927+17 RBL 20 WL 179; FOUND 0.015 REMOVED FROM ORIG 0.040 IN 1'X1' AREAS; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 1225;[02] VERIFIED CORRECTIVE ACTION 1.;[03] BEGAN REMOVING AFT CARGO BAY SIDEWALL SUPPORT BS 887 TO BS947 RBL 20 PER SRM 51-40-02-0G-0;[04] REMOVED AFT CARGO BAY SIDEWALL SUPPORT BS 887 TO BS947 RBL 20 PER SRM 51-40-02-0G-0;[05] LOCATED AND DRILLED NEW AFT CARGO BAY SIDEWALL SUPPORT BS 887 TO BS947 RBL 20 PER SRM 51-40-05-0G-0 AND DWG 147A7500. OK TO INSTALL;[06] VERIFIED LOCATION AND DRILLING OF NEW AFT CARGO BAY SIDEWALL SUPPORT BS 887 TO BS947 RBL 20 PER SRM 51-40-05-0G-0 AND DWG 147A7500. OK TO INSTALL;[07] INSTALLED NEW AFT CARGO BAY SIDEWALL SUPPORT BS 887 TO BS947 RBL 20 PER SRM 51-40-02-0G-0 AND DWG 147A7500;[08] VERIFIED CORRECTIVE ACTION STEP 7 COMPLETED;[09] VERIFIED CORRECT ACTION STEPS 7 AND 8