What was found
FORWARD CARGO BAY BAFFLE BETWEEN BS 500B AND 500C LBL 20 WL 154 IS DAMAGED / [01] CORRECTION TO TASK DETAIL SHOULD STATE ' FORWARD CARGO BAY BAFFLE BETWEEN BS 500B AND 500C LBL 25 WL 154 IS DAMAGED ';[02] REMOVED DAMAGED BAY BAFFLE; LOCATED AND DRILLED NEW BAY BAFFLE BTW BS 500B AND 500C WL 154 LBL 25 IAW SRM 51-40-02-0G-0;51-40-05-0G-0 AND DWG 143A7505. OK TO INSTALL;[03] VERIFIED NEW BAFFLE DRILL UP IAW SRM 51-40-02-0G-0;51-40-05-0G-0 AND DWG 143A7505; OK TO INSTALL.;[04] INSTALLED NEW BAY BAFFLE P/N 143A7510-21 BTW BS 500B AND 500C WL 154 LBL 25 IAW SRM 51-40-02-0G-0 AND DWG 143A7505;[05] VERIFIED CORRECTIVE ACTION STEP 4 COMPLETED.;[06] VERIFIED CORRECTIVE ACTION STEP 4 AND 5 COMPLETED