What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 328 AND BS 344 LBL46 FWD GALLEY AND LAV 2022-148036 / [01] TOOL USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 02-FEB-23; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 02-FEB-23.;[02] REPLACED NEW WEB LOC. FLOOR STRUCTURE LOCATED BETWEEN BS 328 AND BS 344 LBL46 FWD GALLEY AND LAVATORY IAW B737-700 SRM 51-40-01 AND DWG 141A5400 SHEET 44 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.;[03] CORRECTED STEP 2 REPLACED NEW WEB LOC. FLOOR STRUCTURE LOCATED BETWEEN BS 328 AND BS 344 LBL46 FWD GALLEY AND LAVATORY IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 44 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.;[04] REPLACED NEW WEB LOC. FLOOR STRUCTURE LOCATED BETWEEN BS 328 AND BS 344 LBL46 FWD GALLEY AND LAVATORY IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 44 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.