What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 CENTER SECTION 2022-148133 / [01] TOOL USED RADIUS GAUGE SET P/N: S167C S/N: AE-28454 DUE DATE: 17-JUL-22;[02] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 02-FEB-23. TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811019 DUE DATE: 02-FEB-23;[03] REPLACED ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 CENTER SECTION IAW SRM 51-10-02 PARAGRAPH 9 AND SRM 51-40-02 AND DWG #273A9110 SHEET 6 REV A. MATERIAL USED ALUMINUM SHEET CONVERTED FROM 7075-T0 TO CONDITION T73 0.050?. SEE INDIVIDUAL SIGNSOFF BELOW.;[04] REPLACED ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 CENTER SECTION IAW SRM 51-10-02 PARAGRAPH 9 AND SRM 51-40-02 AND DWG #273A9110 SHEET 6 REV A. MATERIAL USED ALUMINUM SHEET CONVERTED FROM 7075-T0 TO CONDITION T73 0.050?. SEE INDIVIDUAL SIGNSOFF BELOW<BR>RII .