What was found
CRACKED INTERCOSTAL UPPER STTACH ANGLE STA 344-360; LBL 50; WL 208. / [01] UPON INVESTIGATION FOUND CRACKED INTERCOASTAL UPPER ATTACH ANGLE IS LOCATED AT BS 380 - 400; LBL 50; WL 208;[02] VERIFIED CRACK TO BE AT BS 380 TO BS 400; LBL 50; NOT AT BS 344-360 LBL 50.;[03] REMOVED DAMAGED INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; LBL 50; WL 208 PER SRM 51-40-02-0G-0.;[04] LOCATED AND DRILLED NEW INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; LBL 50; WL 208 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG# 143A5400. OK TO INSTALL.;[05] VERIFIED CORRECTIVE ACTION 4.;[06] INSTALLED NEW INTERCOSTAL UPPER P/N 143A541U174 ATTACH ANGLE STA 380-400; LBL 50; WL 208 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG# 143A5400.;[07] UPDATED STEP 1.;[08] CERTIFIED ACTIONS 6 AND 7.;[09] VERIFIED CORRECTIVE ACTIONS 6-8. ALL WORK ACCOMPLISHED.;[10] ALL WORK ACCOMPLISHED.