What was found
CABIN FLOOR PANEL 231XF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED PANEL231XF AND FOUND AREA OF PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP FOR REPAIR. IAW B737-700 SRM 53-00-50-2R-1 PAR 3A;C;E&F.VERIFIED MATERIALS AS: BMS 8-201 (A112601); BMS 9-3 (A10273). NEED OK TO BOND.;[02] VERIFIED AND OK TO BOND;[03] BONDED REPAIR PLIES. IAW B737-700 SRM 53-00-50-2R-1 PAR 3K-M. AAR DIGITAL THERMOMETER 30347 150DEG 3HRS.;[04] REPAIRED AREA OF PULLED FIBERS ON UPPER SURFACE OF PANEL 231XF. IAW B737-700 SRM 53-00-50-2R-1; SRM 53-00-50-2R-0.;[05] VERIFIED STEPS 3-4