What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A - BS500D RBL23. / [01] REMOVAL CORROSION ON UPPER SURFACE FROM FLOOR TO SIDEWALL SUPPORT (1).- BS.500A+14' L=1.5' X W=.6' X D=0.015' (2).- BS.500C+17' L=2.' X W=1'. X D=0.020' MAX. MATERIAL LOSS IS 0.020' REMAINING IS 0.020' ORIG. THICKENESS 0.040' BAC1496-444 PER SRM 53-30-53-0I-2; IDENTIFICATION 2 TABLE 2 ITEM[1]; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PARAG. 4.A.(2)(A) DETAIL D. USED TOOL MICROMETER ID:ATS1671;S/N:65093024 DUE DATE:10/2022.;[02] REMOVED FLOOR TO SIDEWALL SUPPORT LOCATED BTW BS 500A - BS 500D RBL 23 WL 156 IAW SRM 51-40-02.;[03] VERIFIED CORRECTIVE ACTION #1;[04] RECEIVED EXTRUSION BAC 1496-444; LOT:1479718-1; LOCATED AND DRILLED BTW BS 500A - BS 500D RBL 23 WL 156 IAW SRM 51-40-05-0G-0. DWG#143A7500. APPLIED CHEMICAL CONVERSION COATING ON NEW PART PER SRM 51-20-01-0G-0. OK TO APPLY PRIME.;[05] VERIFIED CORRECTIVE ACTION #4<BR> OK TO APPLY PRIMER GIVEN;[06] APPLIED PRIMER ON NEW PART PER SOPM 20-41-02.;[07] VERIFIED CORRECTIVE ACTION STEP 6.;[08] ENAMEL AND C.I.C. ACCOMPLISHED IN CUSTOMER CARD TTG8Q004FB92. OK TO INSTALL.;[09] OK TO INSTALL;[10] INSTALLED FLOOR TO SIDEWALL SUPPORT AT FWD. CARGO BAY BTW BS 500A - BS 500D RBL 23 WL 156 IAW SRM 51-40-02-0G-0. DWG#143A7500.;[11] RII INSPECTION COMPLETE;[12] INSPECTION COMPLETE