What was found
CRACK IN RADIUS OF FRAME AT B.S. 312 JUST ABOVE FORWARD ENTRY DOOR CUT OUT. / [01] REMOVED DAMAGE BY TRIMMING FRAME RADIUS AND FLANGE L=0.6' X W=0.5' MAINTAINING 0.5' RADIUS IAW SRM 51-10-02.;[02] VERIFIED CORRECTIVE ACTION #1;[03] REQUEST HFEC INSPECTION ALONG THE TRIM EDGES FOR CRACK FREE CONDITION;[04] ACCOMPLISHED HFEC INSPECTION OF CUTOUT NO CRACK NOTED IAW 737 NDTM PART 6; 51-00-00 PROCEDURE 23 TOOL# ISO000681.;[05] REPAIR ACCOMPLISHED PER EA#22-153-00906;[06] VERIFIED ALL STEPS COMPLETED;[07] COMPLETE