What was found
FWD SERVICE DOOR FWD LOWER STUB BEAM O/B ANGLE CRACKED BS294.5 RBL 58 WL 210 FWD SERVICE DOOR FWD LOWER STUB BEAM CRACKED BS294.5 RBL 58 WL 210 / [01] REMOVED FWD SERVICE DOOR FWD LOWER STUB BEAM O/B ANGLE FROM BS 294.5; RBL-58; WL- 210 IAW SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW FWD SERVICE DOOR FWD LOWER STUB BEAM O/B ANGLE FROM BS 294.5; RBL-58; WL- 210 IAW SRM 51-40-05 OK TO INSTALL;[03] VERIFIED LOCATED AND DRILLED NEW FWD SERVICE DOOR FWD LOWER STUB BEAM O/B ANGLE FROM BS 294.5; RBL-58; WL- 210 IAW SRM 51-40-05.<BR>VERIFIED OK TO INSTALL.;[04] INSTALLED THE NEW FWD SERVICE DOOR FWD LOWER STUB BEAM O/B ANGLE AT BS 294.5; RBL-58; WL- 210 IAW SRM 51-40-02 AND DWG # 141A8310;[05] VERIFIED CORRECTIVE ACTION #4;[06] DRAWING 141A8310 IS REV B (INDICATED AT THE BOTTOM OF PAGE 1 ON ID SHEET 0025);[07] VERIFIED CORRECTIVE ACTION 6; UPDATE IS FOR CORRECTIVE ACTION 4 DRAWING REVISION UPDATE.