What was found
CORROSION ON FWD CARGO BAY DOOR CUT-OUT FWD SHIELD FROM STA 420+5 TO STA 440; RBL 24; WL 156. / [01] NO ALLOWABLE DAMAGE LIMITS IN SRM REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0;[02] VERIFIED;[03] RECEIVED NEW SHIELD P/N:143A8126U21ATSMRO ; LOT:1481125-1 AND LOCATED AND DRILLED AT FCB STA 420+5' TO STA 440 RBL 24 ; WL 156 IAW SRM 51-40-05 AND DWG:143A0080 ID:0013 REV:A.;[04] FIXED MEASUREMENT 22 TO MINOR.;[05] ADDED PART;[06] VERIFIED CORRECTIVE ACTION #3